2800 Base Cabinet, Single System with One 4+0 Clique
One or two 680 systems can be installed in a 2800 4+0 single-clique base cabinet, using Type B, C, or D power:
- A single 680 system can be installed in U-spaces 40-42. U-space 39 must be left empty when a 680 system is installed above it.
- A second 680 system can be installed in U-spaces 36-38. U-space 35 must be left empty when a 680 system is installed above it.
2800 Base Cabinet, Single System with Two 4+0 Cliques
One or two 680 systems can be installed in a 2800 4+0 multi-clique system base cabinet with two 4+0 cliques:
- A single 680 system can be installed in U-spaces 40-42. U-space 39 must be left empty when a 680 system is installed above it.
- A second 680 system can be installed in U-spaces 36-38. U-space 35 must be left empty when a 680 system is installed above it.
2800 Base Cabinet with Two 4+0 Clique Systems
One or two 680 systems can be installed in a 2800 4+0 multi-system base cabinet with two 4+0 clique systems:
- A single 680 system can be installed in U-spaces 28-30. U-space 27 must be left empty when a 680 system is installed above it.
- A second 680 system can be installed in U-spaces 17-19. U-space 16 must be left empty when a 680 system is installed above it.