Base Cabinet, Single 2850 System with One 2+0 Clique and One 4+0 Clique, and One 680 System
Multi-system configuration with two systems. The first system includes one 2-node clique and one 4-node clique, the second system includes one 1-node 680.
2850 product documentation identifies the 680 system as a 680 SMP. The reference to SMP in the legend is a reference to the 680 system.
- A single 680 system can be installed in U-spaces 40-42. U-space 39 must be left empty when a 680 system is installed above it.
Base Cabinet, Single 2850 System with One 2+0 Clique and One 4+0 Clique, and Two 680 Systems
Multi-system configuration with three systems. The first system includes one 2-node clique and one 4-node clique, and the second and third systems each include a 1-node 680 system.
- The first 680 system can be installed in U-spaces 36-38. U-space 35 must be left empty when a 680 system is installed above it.
- The second 680 system can be installed in U-spaces 40-42. U-space 39 must be left empty when a 680 system is installed above it.
Base Cabinet, Single 2850 System with Two 4+0 Cliques and One 2+0 Clique, and One 680 System
Multi-system configuration with two systems. The first system includes two 4-node cliques and one 2-node clique, the second system includes one 1-node 680 system.
- A single 680 system can be installed in U-spaces 40-42. U-space 39 must be left empty when a 680 system is installed above it.