Continuation Code
Usage Notes
The Continuation Code field specifies the processing to be performed when the Continue Request (CLICRQ) function, which is defined for deferred mode LOB processing, is invoked. The value indicates whether the request is for the first, intermediate, or last continuation, or whether processing is to be cancelled.
Note: DBCHINI does not initialize this value.
If this function is needed by the application, the following procedure must be performed prior to calling DBCHCL.
1 Set the Change‑options to “Y”
2 Set the value as follows:
Language |
Variable Name |
COBOL: |
DBNICNT |
C: DBCAREA.H: |
dbniCnt/continuation_code |
Routine |
Action Taken |
DBCHCL: |
reads |
Used by |
Action Taken |
application program |
writes |