BARNC (DSA Network Client) errors are reported in the clienthandler.log and $DSA_LOG_DIR/dsc.log files.
- BSASendData failed
- BSAGetData failed
- Possible causes: An error occurred in the media management software that prevents the backup or restore operation from completing successfully. The message includes additional text indicating the reason for the failure.
- CBB Filter write open failed
- BB Filter write seek failed
- CBB Filter write failed
- Possible Causes (for any of the three errors above): The shared storage area used for Teradata incremental restore is full or is not properly configured.
- Failed to bind any listen sockets.
- Possible causes: An attempt to start the DSA Network Client service was made while it was already running, or another process is using the network port assigned to the DSA Network Client service.
- JMSSessionFactory could not be created
- Possible causes: The ActiveMQ message broker service is not active or cannot be reached.
- No matching file: "Filename"
- Possible causes: An attempt was made to restore an expired or failed backup.
- Read passed end of file
- Possible causes: An attempt was made to restore a corrupted or incomplete backup file.