Checking Time Zone Setting Status - Data Stream Architecture

Teradata Data Stream Architecture (DSA) User Guide

Product
Data Stream Architecture
Release Number
16.10.01
Published
November 2017
Language
English (United States)
Last Update
2018-04-17
dita:mapPath
fyx1509665931452.ditamap
dita:ditavalPath
3150_DSA_UG_1610.ditaval.ditaval
dita:id
B035-3150
Product Category
Software
Teradata Tools and Utilities
Before restoring DBC database, use the dbscontrol utility to check whether the Time Zone is set on the destination system.
  1. From a command prompt on the destination system, run the dbscontrol utility to display general settings:
    #dbscontrol
    > display general
      
      18.System TimeZoneString = American Eastern
    If the return value for System TimeZoneString is anything except Not Set, as in the above example, disable the Time Zone setting before restoring DBC database.