Teradata Database Message 5269 - 5269 - Analytics Database - Teradata Vantage
Teradata® VantageCloud Lake - Analytics Database Messages
- Edition
- Lake
- Product
- Analytics Database
- Teradata Vantage
- Published
- October 2022
- Language
- English (United States)
- Last Update
- 2024-02-26
- dita:mapPath
- tzr1629746512312.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- vza1585613049811
- lifecycle
- latest
- Product Category
- Teradata® Vantage™
- Message
- WARNING: Perform Row-at-a-time inserts instead of Block-at-a-time due to incompatible system/object characteristics.
- Explanation
- A BAR Restore operation cannot restore whole blocks from the archive due to incompatible file system characteristics on the target system. The Restore operation will restore individual rows. It does row-at-a-time inserts and display this warning in the following cases and only when REBLOCK=false (Note that by default REBLOCK=false): 1) Source and target system have different alignment sizes. 2) When archive and restore is between committal and non-committal systems. 3) Source and target have different row formats. 4) When one or more of the backup streams contain AMPs belong to a cluster that has more than 2 amps and there was a down AMP in the cluster when the backup was taken.
- Generated By
- DBS BAR
- For Whom
- End user of BAR Restore.
- Notes
- This is an informational message, not a fatal error. The Restore operation will complete successfully.
- Remedy
- After completion of the Restore, contact Field Engineer and take appropriate action if necessary.