Message
Excess nodes found in clique.
Explanation
Too many nodes are assigned to a single clique in Vconfig GDO. A clique can support a maximum of 16 nodes.
Generated By
PDE Initialization.
For Whom
System Support Representative.
Notes
None
Remedy
Correct the configuration and then restart PDE. This could also be due to corruption of the VConfig GDO. Run vconfig -x to display the configuration info in this GDOs. If it is not correct, rerun vconfig and force a TPA restart.