- Message
- The argument for an INOUT/OUT parameter "%VSTR" is invalid.
- Explanation
- The argument for an OUT parameter to a stored procedure can be only parameter name; a value expression can not be specified in an argument. For inner procedure call a value expression cannot be specified for an INOUT/OUT parameter .
- Generated By
- OPT modules.
- For Whom
- End User.
- Notes
- None
- Remedy
- Replace the specified value expression specified as an argument to the OUT parameter of the procedure with the corresponding OUT parameter name and resubmit the CALL request. If it is a nested call change the outer procedure definition so that in inner call either INOUT or OUT parameter does not have value expression and recompile the outer procedure and submit call.