Purpose
Synchronizes the specified table from the source system to the destination system.
Syntax
OBJECT RESYNC {<tablename |id:object id>} [FROM tdpid1] [ TO tdpid2] [TIMEOUT '<timeout (seconds)>'];Parameters
- tablename
- Fully qualified name of the target object.
- object id
- Managed object id of the target object.
- tdpid1
- Unique identifier (TDPID) of a source Teradata Database system.
- tdpid2
- Unique identifier (TDPID) of a target Teradata Database system.
- timeout (seconds)
- The timeout, in seconds, to use for the operation.
Example
unityadmin> OBJECT RESYNC db0.t1000 FROM sdt29630 TO sdt29631 TIMEOUT 60; Operation Number : 3 Operation Name : Resyncing Object User : admin User Name : Main Administration User Start Time : 07/22 10:29:24 Updates: 07/22 10:29:24 [-] Info: Resyncing table db0.t1000 from sdt29630 to sdt29631 using timeout 60 07/22 10:29:26 [-] Info: Activating table on target system ( setting to Active ) 07/22 10:29:26 [-] Info: Successfully activated the table on 2 systems 07/22 10:29:26 [-] Info: Operation finished 07/22 10:29:26 [-] Info: Table resync completed Status : Finished (1) Finish Time : 07/22 10:29:26